Walther Trowal TFM 49/21 vs TFM 150/125 vibratory finishing catalog comparison

Review TFM 49/21 and TFM 150/125 from the official Walther Trowal TFM brochure marked 04/21, physical PDF page2. Filter 7 source fields and record your part, fixture or separation, site and acceptance questions before downloading the current review. Volume and drive entries retain their printed physical bases. The captured current web table is separate from the versioned PDF and does not establish an offered machine.

Walther Trowal TFM 49/21 vs TFM 150/125 vibratory finishing catalog comparison - usable-volume-review diagram - Jintaijin
Original source-data diagram; Walther Trowal 04/21, physical PDF page2. No actual trial or current configuration approval.

Compare catalog fields and record configuration questions

Choose a source field group; optionally record your own review requirements.

Versioned catalog rows

Source fieldTFM 49/21TFM 150/125
Drive power - standard version (kW; motor multiplicity retained)1 x 0.371 x 7.0
Drive power - ball burnishing version (kW; multiplicity/availability retained)1 x 0.75n.a.**
Lining thickness (mm; not a material compatibility approval)1025
Usable volume (L; not part batch load)151,650
Outlet diameter (mm; not separation aperture or part-fit approval)140320
Number of outlets (not throughput)12
Standard speed and optional inverter equipment range (rpm)Standard 1,500 RPM; optional inverter range 1,000 - 2,800 RPMStandard 1,500 RPM; optional inverter range 1,000 - 2,800 RPM

Separate usable volume from part batch load

The 04/21 PDF lists TFM 49/21 with 15 L usable volume and TFM 150/125 with 1,650 L. Neither number establishes a part-only load, cycle time, production rate or approved operating fill. Review the actual part arrangement, media grade and media-to-parts occupancy with the trial owner.

Review configuration and geometry bases

The PDF outlet-diameter entries are 140 mm for TFM 49/21 and 320 mm for TFM 150/125; outlet counts are 1 and 2. These are outlet descriptions, not separation apertures or unloading-rate measurements. Lining thicknesses are 10 mm and 25 mm. Thickness alone does not specify lining material, acid resistance, media compatibility or wear life. Review the actual part/media exit path and required fixture or dividers; lettered dimensions are not relabeled as length, width or height.

Walther Trowal TFM 49/21 vs TFM 150/125 vibratory finishing catalog comparison - configuration-basis-review diagram - Jintaijin
Original source-data diagram; Walther Trowal 04/21, physical PDF page2. No actual trial or current configuration approval.

Keep drive units and speed statements separate

Standard drive entries are 1 x 0.37 kW for TFM 49/21 and 1 x 7.0 kW for TFM 150/125. Their ball-burnishing entries are 1 x 0.75 and n.a.**, under the separate kW row. Preserve the 1 x or2 x motor multiplicity; this page does not silently sum a site load or infer energy use. The shared footnote gives standard1,500rpm and optional frequency-inverter range1,000-2,800rpm. Optional control is not confirmed as installed, and the equipment range is not a suitable process recipe.

Walther Trowal TFM 49/21 vs TFM 150/125 vibratory finishing catalog comparison - drive-version-review diagram - Jintaijin
Original source-data diagram; Walther Trowal 04/21, physical PDF page2. No actual trial or current configuration approval.

Confirm the actual version and installed options

The n.a.** footnote explicitly means not available for ball burnishing in this brochure version. It is not zero power, a missing cell or a current quotation decision. The PDF marks this for TFM120/91,150/125 and210/150. Standard and ball-burnishing configurations remain separate. Special fixtures or dividers may be needed when part contact is unacceptable; availability and performance require supplier and trial review.

Keep current-web differences visible

TFM 49/21: power is 1 x 0.37 in the PDF and 1x0.55 under current web label "Power, standard version (kW)". TFM 49/21: outlet_diameter is 140 in the PDF and 100 under current web label "Outlet diameter". 1 x and2 x drive entries retain motor multiplicity; no total site load or energy calculation. n.a.** means not available for ball burnishing in this brochure; it is not missing data or numeric zero. Keep versions and physical bases separate and request the actual offered specification.

Official current TFM product page, captured2026-10-05. Selected numeric rows were compared; this is not an exhaustive reconciliation of drawings, options, physical power bases or offered configurations.

Source and scope

Official TFM brochure, 04/21, physical page2; captured2026-10-05. Independent Walther Trowal reference. No Jintaijin supply, partnership, equivalent machine, actual finishing result, medical/aerospace qualification or current offer is established. User notes are USER_RECORDED_NOT_VERIFIED. Diagrams are original source-data references, not product photos or customer evidence.

Questions about this pair

How do TFM 49/21 and TFM 150/125 compare in usable volume?

The 04/21 PDF lists TFM 49/21 with 15 L usable volume and TFM 150/125 with 1,650 L. Neither number establishes a part-only load, cycle time, production rate or approved operating fill. Review the actual part arrangement, media grade and media-to-parts occupancy with the trial owner.

What configuration or geometry fields need confirmation?

The PDF outlet-diameter entries are 140 mm for TFM 49/21 and 320 mm for TFM 150/125; outlet counts are 1 and 2. These are outlet descriptions, not separation apertures or unloading-rate measurements. Lining thicknesses are 10 mm and 25 mm. Thickness alone does not specify lining material, acid resistance, media compatibility or wear life. Review the actual part/media exit path and required fixture or dividers; lettered dimensions are not relabeled as length, width or height.

Can these drive rows be used as power or process settings?

Standard drive entries are 1 x 0.37 kW for TFM 49/21 and 1 x 7.0 kW for TFM 150/125. Their ball-burnishing entries are 1 x 0.75 and n.a.**, under the separate kW row. Preserve the 1 x or2 x motor multiplicity; this page does not silently sum a site load or infer energy use. The shared footnote gives standard1,500rpm and optional frequency-inverter range1,000-2,800rpm. Optional control is not confirmed as installed, and the equipment range is not a suitable process recipe.

Which version and availability statements must remain separate?

The n.a.** footnote explicitly means not available for ball burnishing in this brochure version. It is not zero power, a missing cell or a current quotation decision. The PDF marks this for TFM120/91,150/125 and210/150. Standard and ball-burnishing configurations remain separate. Special fixtures or dividers may be needed when part contact is unacceptable; availability and performance require supplier and trial review.

Does the current official website agree with the PDF?

TFM 49/21: power is 1 x 0.37 in the PDF and 1x0.55 under current web label "Power, standard version (kW)". TFM 49/21: outlet_diameter is 140 in the PDF and 100 under current web label "Outlet diameter". 1 x and2 x drive entries retain motor multiplicity; no total site load or energy calculation. n.a.** means not available for ball burnishing in this brochure; it is not missing data or numeric zero. Keep versions and physical bases separate and request the actual offered specification.

Related review tools

Prepare a sample review enquiry

For SurfacePolish equipment discussions, provide your part drawing, finishing objective, fixture and media restrictions, and acceptance method. This reference does not confirm third-party machine supply.

Open the SurfacePolish enquiry form

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact