Walther Trowal TMV 345/55 vs TMV 175/85 vibratory finishing catalog comparison
Review TMV 345/55 and TMV 175/85 from the official Walther Trowal TMV brochure marked 12/20, physical PDF page2. Filter 6 source fields and record your part, fixture or separation, site and acceptance questions before downloading the current review. Volume and drive entries retain their printed physical bases. The captured current web table is separate from the versioned PDF and does not establish an offered machine.
Compare catalog fields and record configuration questions
Versioned catalog rows
| Source field | TMV 345/55 | TMV 175/85 |
|---|---|---|
| Drive power - standard version (kW; not measured consumption) | 11.0 | 11.0 |
| Drive power - ball burnishing version (kW; availability retained) | 18.5 | 22.0 |
| Quantity of imbalance units (not motor count) | 4 | 2 |
| Lining thickness (mm; not material compatibility approval) | 22 | 25 |
| Usable volume (L; not part batch load) | 735 | 895 |
| Standard speed and optional inverter statement (rpm; no PDF range) | Standard 1,500 RPM; optional frequency inverter; no range printed in PDF | Standard 1,500 RPM; optional frequency inverter; no range printed in PDF |
Separate usable volume from part batch load
The 12/20 PDF lists TMV 345/55 with 735 L usable volume and TMV 175/85 with 895 L. Neither number establishes a part-only load, cycle time, production rate or approved operating fill. Review the actual part arrangement, media grade and media-to-parts occupancy with the trial owner.
Review configuration and geometry bases
The quantity-of-imbalance-unit entries are 4 for TMV 345/55 and 2 for TMV 175/85. These are unbalance-system counts, not a confirmed number of motors. Lining thicknesses are 22 mm and 25 mm. Counts and thickness do not establish part protection, circulation intensity, energy efficiency, material compatibility or maintenance intervals. Only the12 explicit table columns are adopted; narrative modular widths/lengths do not establish parameters for unlisted combinations. Lettered drawing dimensions are not used to calculate a floor plan.
Keep drive units and speed statements separate
Standard-version power entries are 11.0 kW for TMV 345/55 and 11.0 kW for TMV 175/85. Separate ball-burnishing entries are 18.5 and 22.0 under the kW row. Standard speed is1,500rpm; the optional frequency inverter has no numeric speed range printed in this PDF. The current website gives a range, but it is not imported into the versioned record, and neither is the TFM brochure range. No process setting, summed site load, measured energy use or output rate is derived.
Confirm the actual version and installed options
The n.a.** footnote explicitly means not available for ball burnishing in this PDF version. TMV260/65,345/65,260/85 and345/85 carry that marker. It is not numeric zero or generic missing data. Keep standard and ball-burnishing versions separate, and confirm the actual offered system and workpiece trial. A powerful-drive narrative does not prove cycle-time improvement or a finishing result for your part.
Keep current-web differences visible
No numeric difference was found in the selected rows for this pair. This limited comparison does not confirm agreement of all current specifications. Quantity of imbalance units is not a motor count. PDF optional inverter has no numeric range; current web gives1,000-2,800. Keep bases separate; do not import TFM or current-web range into PDF records. Only12 explicit table model columns adopted; modular narrative lengths do not create additional parameter records. Keep versions and physical bases separate and request the actual offered specification.
Official current TMV product page, captured2026-10-05. Selected numeric rows were compared; this is not an exhaustive reconciliation of drawings, options, physical power bases or offered configurations.
Source and scope
Official TMV brochure, 12/20, physical page2; captured2026-10-05. Independent Walther Trowal reference. No Jintaijin supply, partnership, equivalent machine, actual finishing result, medical/aerospace qualification or current offer is established. User notes are USER_RECORDED_NOT_VERIFIED. Diagrams are original source-data references, not product photos or customer evidence.
Questions about this pair
How do TMV 345/55 and TMV 175/85 compare in usable volume?
The 12/20 PDF lists TMV 345/55 with 735 L usable volume and TMV 175/85 with 895 L. Neither number establishes a part-only load, cycle time, production rate or approved operating fill. Review the actual part arrangement, media grade and media-to-parts occupancy with the trial owner.
What configuration or geometry fields need confirmation?
The quantity-of-imbalance-unit entries are 4 for TMV 345/55 and 2 for TMV 175/85. These are unbalance-system counts, not a confirmed number of motors. Lining thicknesses are 22 mm and 25 mm. Counts and thickness do not establish part protection, circulation intensity, energy efficiency, material compatibility or maintenance intervals. Only the12 explicit table columns are adopted; narrative modular widths/lengths do not establish parameters for unlisted combinations. Lettered drawing dimensions are not used to calculate a floor plan.
Can these drive rows be used as power or process settings?
Standard-version power entries are 11.0 kW for TMV 345/55 and 11.0 kW for TMV 175/85. Separate ball-burnishing entries are 18.5 and 22.0 under the kW row. Standard speed is1,500rpm; the optional frequency inverter has no numeric speed range printed in this PDF. The current website gives a range, but it is not imported into the versioned record, and neither is the TFM brochure range. No process setting, summed site load, measured energy use or output rate is derived.
Which version and availability statements must remain separate?
The n.a.** footnote explicitly means not available for ball burnishing in this PDF version. TMV260/65,345/65,260/85 and345/85 carry that marker. It is not numeric zero or generic missing data. Keep standard and ball-burnishing versions separate, and confirm the actual offered system and workpiece trial. A powerful-drive narrative does not prove cycle-time improvement or a finishing result for your part.
Does the current official website agree with the PDF?
No numeric difference was found in the selected rows for this pair. This limited comparison does not confirm agreement of all current specifications. Quantity of imbalance units is not a motor count. PDF optional inverter has no numeric range; current web gives1,000-2,800. Keep bases separate; do not import TFM or current-web range into PDF records. Only12 explicit table model columns adopted; modular narrative lengths do not create additional parameter records. Keep versions and physical bases separate and request the actual offered specification.
Related review tools
Prepare a sample review enquiry
For SurfacePolish equipment discussions, provide your part drawing, finishing objective, fixture and media restrictions, and acceptance method. This reference does not confirm third-party machine supply.
Open the SurfacePolish enquiry form