Post-finishing measurement uncertainty interval review

When a finished feature is close to a drawing limit, keep its reading and the applicable reported expanded uncertainty together. Compare their symmetric interval with your entered limits, then export the arithmetic record for the person applying the agreed inspection decision rule.

Post-finishing measurement uncertainty interval review - Keep the reading and reported U together - Jintaijin
Keep the reading and reported U together. Original illustration.

Review a reported measurement interval

Enter all four values in millimetres. U must be nonnegative and must refer to this feature, instrument and measurement method. This tool takes a reported U; it does not evaluate one. Numerical limits are treated as closed endpoints here. Numeric inputs support up to 18 normalized decimal places and magnitude 1000000 mm.

Enter the reading, reported U and agreed numeric limits.

Examples below are illustrative arithmetic, not measured parts or recommended tolerances.

Post-finishing measurement uncertainty interval review - Three illustrative interval positions - Jintaijin
Three illustrative interval positions. Original illustration.

Read the relation as arithmetic

RelationEndpoint comparison
Containedy-U is at or above L; y+U is at or below H
Belowy+U is strictly below L
Abovey-U is strictly above H
Intersects or touchesOther positions, including a boundary contact while extending outside

Lower interval margin is (y-U)-L. Upper interval margin is H-(y+U). Negative margins show the interval extending beyond the corresponding entered limit. They are not material-removal allowances or machine capability values.

Post-finishing measurement uncertainty interval review - Separate interval arithmetic from acceptance - Jintaijin
Separate interval arithmetic from acceptance. Original illustration.

Prepare the post-finishing inspection review

Record the drawing revision, feature location, datum, inspection method and applicable uncertainty report. Match the unit before entering the reading and U. Record how the customer and supplier agreed to account for uncertainty. If the feature was compared before and after finishing, retain those observations separately; this single-reading interval does not show what caused a change.

Method references and limits

JCGM 100 describes the symmetric representation y±U for a reported expanded uncertainty. JCGM 106 distinguishes tolerance limits from acceptance limits and discusses decision rules. The 2026 amendment to JCGM 100 concerns nonlinear measurement models; this tool neither propagates an uncertainty model nor selects U.

Original review arithmetic and diagrams; no standard text or source figure is republished here, and no endorsement is implied.

Measurement review questions

Does contained mean the finished part is accepted?

No. This is the numerical position of the entered interval. The agreed decision rule, specification and measurement report govern acceptance.

Does U imply a fixed coverage probability?

No. Use the U supplied for this measurement. This tool does not choose a coverage factor or infer a probability.

What if I enter zero uncertainty?

The interval collapses to the entered reading. A zero input does not prove that actual measurement uncertainty is zero.

Are example dimensions real trial results?

No. The examples demonstrate arithmetic with illustrative limits, readings and U values; they are not customer or manufacturing data.

Related inspection records

Record the same-feature signed dimensional change

Record the agreed part acceptance basis

Discuss feature protection and inspection records for a finishing trial

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact