Compare FKS 15.1 A2 and FKS 35.1 A2 using the Roesler high-energy disc factsheet, physical page 2, revision 04/2023. Read gross operating volume, machine dimensions and original power entries side by side. Select an explicitly listed dimension condition, optionally enter your own three maxima, and download the current comparison for supplier review. Confirm current configuration and complete drawings before selecting equipment.

Roesler FKS 15.1 A2 vs FKS 35.1 A2: catalog comparison - gross-volume diagram - Jintaijin
Original gross volume diagram for this pair. Source table page 2, revision04/2023; data illustration.

Read the exact configuration and source fields

Source fieldFKS 15.1 A2FKS 35.1 A2
Gross operating volume, original entry120 L260 L
Base length2620 mm3250 mm
Length with screening unit, when listedNot listedNot listed
Machine width2260 mm2710 mm
Machine height (factsheet label)2320 mm2360 mm
Maximum loading-unit height in tilted position2560 mm3110 mm
Processing-bowl diameter640 mm800 mm
Screening-unit discharge height880 mm980 mm
Rotary-spinner drive power, original entry4,0 (5,5) kW11,0 (15,0) kW
Total installed power, original entry11,0 kW22,0 kW
Vibratory screening unit, when listedNot listedNot listed
Screening-area L x W dimensions, when listedNot listedNot listed

The A2 table prints gross operating volume as 120 L for FKS 15.1 A2 and 260 L for FKS 35.1 A2. The scalar right-minus-left difference is 140 L. Gross operating volume does not establish permissible workpiece loading, batch mass, media ratio or throughput.

The A2 factsheet separates machine height from the maximum height of the loading unit in its tilted position. The brochure drawing uses C for machine height, while its table labels C as Width; this page follows the factsheet Height label and retains that discrepancy. Total installed power and spinner power are different source fields.

Compare with your own dimension limits

Select a listed dimension condition. Leave all three inputs blank for catalog comparison, or enter all three positive decimal maxima. No limits are prefilled. A passing comparison is not installation or process approval.

Compare the listed values, or enter all three optional dimension limits.
Roesler FKS 15.1 A2 vs FKS 35.1 A2: catalog comparison - dimension-conditions diagram - Jintaijin
Original dimension conditions diagram for this pair. Source table page 2, revision04/2023; data illustration.

Compare separate dimension conditions

Listed base length/width/height is 2620/2260/2320 mm for FKS 15.1 A2 and 3250/2710/2360 mm for FKS 35.1 A2. The right-minus-left changes are 630 mm in length, 450 mm in width and 40 mm in machine height.

Length with screening unit is not listed for both records. The corresponding condition is unavailable; the tool does not substitute zero or base length.

The loading unit reaches 2560 versus 3110 mm in the listed tilted position. In tilt mode the height screen checks the larger of machine height and loading-unit tilt height for each model. This is arithmetic on two catalog values, not a supplier-approved installation envelope.

These values do not include inferred maintenance, utilities, guarding, lifting paths or floor-loading allowances. Obtain the complete drawing for the offered configuration and review it with the supplier. Processing-bowl diameter is not a permissible maximum workpiece size; evaluate geometry, sensitivity, media circulation, separation and sample-trial results.

Roesler FKS 15.1 A2 vs FKS 35.1 A2: catalog comparison - power-fields diagram - Jintaijin
Original power fields diagram for this pair. Source table page 2, revision04/2023; data illustration.

Keep volume and power on their source basis

Rotary-spinner drive power is printed as 4,0 (5,5) versus 11,0 (15,0) kW. At least one entry includes a parenthetical power option; the original expressions are retained and no scalar difference is calculated. Total installed power is 11,0 versus 22,0 kW. Parenthetical entries retain their original form. Spinner power and total installed power cannot be interchanged; neither is measured operating consumption.

Two-factor volume and parenthetical power entries remain visible as printed. No unspecified motor option is selected. Catalog power is not a measured electricity-use figure and does not predict polishing time, finish quality or parts per hour.

Source: Roesler High Energy Disc Systems factsheet, physical page 2, revision04/2023. The EN.231.02 revision04/2023 brochure supplies additional drawing context from the same publisher; it is not independent testing.

Confirm current availability, exact configuration, controls, utilities and trial conditions with the manufacturer. No Jintaijin equivalence or manufacturer partnership is established.

Questions about this pair

What changes between FKS 15.1 A2 and FKS 35.1 A2?

The A2 table prints gross operating volume as 120 L for FKS 15.1 A2 and 260 L for FKS 35.1 A2. The scalar right-minus-left difference is 140 L. Gross operating volume does not establish permissible workpiece loading, batch mass, media ratio or throughput. Listed base length/width/height is 2620/2260/2320 mm for FKS 15.1 A2 and 3250/2710/2360 mm for FKS 35.1 A2. The right-minus-left changes are 630 mm in length, 450 mm in width and 40 mm in machine height.

Which dimension conditions can I select for this pair?

Length with screening unit is not listed for both records. The corresponding condition is unavailable; the tool does not substitute zero or base length. The loading unit reaches 2560 versus 3110 mm in the listed tilted position. In tilt mode the height screen checks the larger of machine height and loading-unit tilt height for each model. This is arithmetic on two catalog values, not a supplier-approved installation envelope.

Can the power entries estimate operating cost or process speed?

Rotary-spinner drive power is printed as 4,0 (5,5) versus 11,0 (15,0) kW. At least one entry includes a parenthetical power option; the original expressions are retained and no scalar difference is calculated. Total installed power is 11,0 versus 22,0 kW. Parenthetical entries retain their original form. Spinner power and total installed power cannot be interchanged; neither is measured operating consumption. The source table does not list a process-speed recommendation or electrical frequency. It does not establish a cycle time, media recipe or energy saving for your workpiece.

What does a passing three-limit screen mean?

It means the selected listed length, width and height condition meets your three entered maxima. In tilt mode the height check includes both machine and loading-unit tilted heights. Leave all three limits blank for catalog comparison, or enter all three positive decimal limits. This screen does not approve guarding, service access, floor loading, utilities, loading paths, part fit or process suitability. Ask the supplier for complete drawings and a workpiece trial.

Related trial and inspection tools

Discuss your workpiece and sample-trial requirements with Jintaijin

Prepare a high-appearance machinery review

Use this local checker to identify missing part and inspection information. It prepares a technical-review brief; it does not approve a machine, process recipe or production result.

Complete the part details to prepare a review brief.

Open the enquiry form for this page

Plan batch capacity from trial measurements

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact