Jintaijin | Independent catalog reference
Roesler R 150 DL vs R 220 DL: catalog comparison
Compare R 150 DL and R 220 DL using Roesler's EN.145.22 catalog, revision 04/2023, physical page 17. Inspect total bowl volume, listed geometry and the original connected-load entry. Enter your own three geometry limits or leave them blank, then download the current result. Confirm current drawings, loading and offered configuration with the supplier before selecting equipment.
Listed specification table
| Source field | R 150 DL | R 220 DL |
|---|---|---|
| Total bowl volume | 190 L | 370 L |
| Maximum outer diameter | 1000 mm | 1080 mm |
| Inner diameter | 700 mm | 948 mm |
| Machine height at bowl upper edge | 1070 mm | 1405 mm |
| Media unload plug height | 455 mm | 700 mm |
| Bowl height (raw; unit not stated) | 500 | 530 |
| Connected load (raw catalog entry, kW) | 0.75 | 3.0/5.0 |
The catalog lists 190 L for R 150 DL and 370 L for R 220 DL: a right-minus-left difference of 180 L. These are total bowl volumes, not allowable part loads or throughput.
Inner diameter changes from 700 to 948 mm; maximum outer diameter from 1000 to 1080 mm. The bowl-height row gives raw values 500 and 530, but its label states no unit in either reviewed document. This page retains that raw row without assigning millimetres or using it in calculations. Inner diameter alone does not establish permissible part fit, fixturing or media flow.
Compare with your own catalog limits
Leave all three inputs blank for catalog comparison. Enter all three to screen the listed values against your own limits. No limits are prefilled. Total volume and inner diameter remain catalog fields, not part-load or fit approval.
Geometry and loading review
Inner diameter changes from 700 to 948 mm; maximum outer diameter from 1000 to 1080 mm. The bowl-height row gives raw values 500 and 530, but its label states no unit in either reviewed document. This page retains that raw row without assigning millimetres or using it in calculations. Inner diameter alone does not establish permissible part fit, fixturing or media flow.
Ask for a current drawing showing guarding, utilities, service access and floor-loading requirements. Review part geometry, material, sensitivity, fixturing and media flow in a referenced sample trial. The listed bowl volume cannot determine packing fraction, batch weight, cycle time, media ratio or output per hour.
Electrical fields and source basis
Connected load is listed as 0.75 versus 3.0/5.0 kW. R 220 DL has the composite entry 3.0/5.0. The documents reviewed do not establish its electrical interpretation. The tool preserves that entry and omits a scalar connected-load difference; it does not select one number or add the two.
Source: Roesler rotary vibrators catalog EN.145.22, revision 04/2023, physical page 17. All displayed entries were also checked against page 2 of the official rotary-vibrator factsheet, revision 04/2023. This is same-publisher corroboration. It does not prove measured values or the current build.
Confirm the actual configuration, electrical supply, permissible loading and availability with the manufacturer. No current Jintaijin equivalent or manufacturer partnership is established.
Questions about this pair
What changes between R 150 DL and R 220 DL?
The catalog lists 190 L for R 150 DL and 370 L for R 220 DL: a right-minus-left difference of 180 L. These are total bowl volumes, not allowable part loads or throughput. Inner diameter changes from 700 to 948 mm; maximum outer diameter from 1000 to 1080 mm. The bowl-height row gives raw values 500 and 530, but its label states no unit in either reviewed document. This page retains that raw row without assigning millimetres or using it in calculations. Inner diameter alone does not establish permissible part fit, fixturing or media flow.
How should the connected-load entries be read?
Connected load is listed as 0.75 versus 3.0/5.0 kW. R 220 DL has the composite entry 3.0/5.0. The documents reviewed do not establish its electrical interpretation. The tool preserves that entry and omits a scalar connected-load difference; it does not select one number or add the two.
What do the three optional limits check?
The tool compares total bowl volume against your entered minimum, inner diameter against your entered minimum and maximum outer diameter against your entered maximum. Enter all three positive decimal values or leave all three blank. Passing these listed-value checks does not approve a part, process, permissible load or installation.
Do these catalog values establish current equipment or equivalence?
These source values are from revision 04/2023. Confirm the actual offered configuration and availability with Roesler. The same-publisher factsheet corroborates table entries but is not an independent measurement. No Jintaijin equivalence or manufacturer partnership is established.
Related trial and inspection tools
Discuss your workpiece and sample-trial requirements with Jintaijin