Jintaijin | Independent rotary-vibrator catalog reference

Roesler R 220 EC vs R 320 EC: catalog comparison

Within the EC series table, total bowl volume changes from 220 L to 320 L, while processing channel width changes from 260 mm to 290 mm. These values describe the listed bowl and channel, not a permissible workpiece load or size.

Basis: Roesler EN.145.22 revision04/2023, physical page 11, EC series. Current configuration and availability are not verified.

Roesler R 220 EC vs R 320 EC: catalog comparison - volume source-based data diagram - Jintaijin
Original volume data diagram from the EC series table, page 11. It is not an equipment photograph or installation drawing.

Versioned specification differences

Catalog fieldR 220 ECR 320 ECRight minus left
Total bowl volume220 L320 L100 L
Processing channel width260 mm290 mm30 mm
Listed maximum outer diameter1200 mm1280 mm80 mm
Connected load3 kW3 kW0 kW

The maximum outer diameter changes by 80 mm (1200 to 1280 mm). Connected load changes by 0 kW (3 to 3 kW). Read each field independently; a diameter does not establish rectangular installation space and connected load does not predict measured operating consumption.

Compare catalog entries against your own limits

Leave all four fields blank for the catalog comparison. For a limit screen, enter all four positive values in the displayed units. No limit is prefilled. These are catalog screening conditions, not part loading or site-installation limits.

Catalog comparison ready. Limits are optional; enter all four to include a catalog screen.
Roesler R 220 EC vs R 320 EC: catalog comparison - dimensions source-based data diagram - Jintaijin
Original dimensions data diagram from the EC series table, page 11. It is not an equipment photograph or installation drawing.

Keep channel dimensions separate from installation dimensions

The maximum outer diameter changes by 80 mm (1200 to 1280 mm). Connected load changes by 0 kW (3 to 3 kW). Read each field independently; a diameter does not establish rectangular installation space and connected load does not predict measured operating consumption.

Channel width is one listed geometry value. Part geometry, freedom of movement, media access, separation and collision risk need a workpiece-specific review. Obtain the current installation drawing for access, height, guarding, service space, utilities and floor loading; do not square the listed diameter to invent a footprint.

Roesler R 220 EC vs R 320 EC: catalog comparison - basis source-based data diagram - Jintaijin
Original basis data diagram from the EC series table, page 11. It is not an equipment photograph or installation drawing.

Source and electrical-value basis

The original Roesler rotary-vibrator catalog, EN.145.22 revision04/2023, physical page 11, supplies the EC series facts. Original diagrams summarize those values without reusing OEM photos.

Within the EC series table, total bowl volume changes from 220 L to 320 L, while processing channel width changes from 260 mm to 290 mm. These values describe the listed bowl and channel, not a permissible workpiece load or size.

Connected load is retained in kW exactly as a catalog field. It is not a measured energy consumption, a price estimate or an identified individual motor rating. Confirm the actual electrical connection and operating configuration with the supplier. This independent reference does not establish a Roesler partnership or Jintaijin equivalence.

Questions about this model pair

What differs between R 220 EC and R 320 EC?

Within the EC series table, total bowl volume changes from 220 L to 320 L, while processing channel width changes from 260 mm to 290 mm. These values describe the listed bowl and channel, not a permissible workpiece load or size. The maximum outer diameter changes by 80 mm (1200 to 1280 mm). Connected load changes by 0 kW (3 to 3 kW). Read each field independently; a diameter does not establish rectangular installation space and connected load does not predict measured operating consumption.

Does total bowl volume predict usable part load?

No. Media filling, parts, process conditions and permissible loads need supplier confirmation and a referenced trial. The volume here is the total bowl volume from the source table.

What does the optional limit screen establish?

It checks whether the listed total volume and channel width meet your entered minima, and the listed maximum diameter and connected load meet your entered maxima. All four fields are required if any is entered. Passing these arithmetic checks is not process, part-fit, electrical or installation approval.

Are these current specifications or Jintaijin equivalents?

The values are Roesler EN.145.22 revision04/2023, physical page 11, for the EC series. Current builds and availability need supplier confirmation. These values do not describe a Jintaijin machine or establish equivalence.

Related trial and inspection tools

Discuss your workpiece and sample-trial requirements with Jintaijin

Prepare a high-appearance machinery review

Use this local checker to identify missing part and inspection information. It prepares a technical-review brief; it does not approve a machine, process recipe or production result.

Complete the part details to prepare a review brief.

Open the enquiry form for this page

Plan batch capacity from trial measurements

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home