Compare R 350 AB and R 750 AB on the printed approximate wastewater-flow, tank-volume and layout basis in Roesler brochure EN.154.21, revision07/2026. Filter the source fields, enter your own liquid-flow requirement and optional solids concentration, and export the current review. Use the original labels to prepare a supplier discussion and fluid trial before choosing an offered configuration.

Roesler R 350 AB vs R 750 AB: recirculation tank catalog comparison - capacity-basis diagram - Jintaijin
Original model-pair data diagram. Official brochure page 11, revision07/2026.

Compare the original printed entries

FieldR 350 ABR 750 AB
VolumeTank volume (l)
350 l
Tank volume (l)
750 l
FlowSuitable for waste water volumes (l/h)
ca. 70 l/h
Suitable for waste water volumes (l/h)
ca. 150 l/h
DimensionsTank dimensions lxwxh (mm)
1,150 x 760 x 520 mm
Tank dimensions lxwxh (mm)
1,990 x 970 x 520 mm
HeightInlet height dirty water (mm)
440 mm
Inlet height dirty water (mm)
440 mm

R 350 AB lists ca. 70 l/h; R 750 AB lists ca. 150 l/h. The ca. prefix means approximate suitable wastewater flow, not a guaranteed maximum. Tank volume is a separate inventory value, not a tested settling time.

Review source fields and your liquid requirements

Enter your own flow in l/h or l/min. Solids concentration is optional and requires a liquid quantity. No values are prefilled.

Compare source fields, or enter your liquid quantity and optional solids concentration.
Roesler R 350 AB vs R 750 AB: recirculation tank catalog comparison - layout-basis diagram - Jintaijin
Original model-pair data diagram. Official brochure page 11, revision07/2026.

Layout and liquid routing

Tank volumes: R 350 AB 350 l; R 750 AB 750 l. Printed dimensions: 1,150 x 760 x 520 mm versus 1,990 x 970 x 520 mm. Dirty-water inlet height: 440 mm versus 440 mm. Check a current layout drawing and gravity-feed levels; the footprint is not a service-clearance envelope.

The source describes cascade precipitation/separation of metal and media fines, removable partitions and an adjustable pulse-controlled compressed-air diaphragm pump. It does not give a removal curve, particle cut size or sludge-cleaning interval.

Roesler R 350 AB vs R 750 AB: recirculation tank catalog comparison - review-boundary diagram - Jintaijin
Original model-pair data diagram. Official brochure page 11, revision07/2026.

Prepare the fluid trial and supplier review

Record the liquid origin, metals processed, media fines, free or emulsified oil, temperature and variability across a shift. Define the desired cleaning effect and how inlet and outlet samples will be collected and evaluated. Keep the expected liquid quantity separate from captured sludge, wet cake and usable storage. Ask the supplier to identify the actual tank, pump, filter and control configuration before layout or operating-cost decisions.

Check current tank drawings, inlet levels, piping, pump air supply, partition removal and cleaning access. Printed dimensions do not include every connection or service space.

Source: Roesler centrifuge technology and process-water brochure EN.154.21, physical page 11, revision07/2026. Original fields are retained. This independent reference does not establish Jintaijin equipment equivalence, manufacturer partnership, current availability, installation approval or a guaranteed result.

Questions about this pair

What is the printed capacity difference between R 350 AB and R 750 AB?

R 350 AB lists ca. 70 l/h; R 750 AB lists ca. 150 l/h. The ca. prefix means approximate suitable wastewater flow, not a guaranteed maximum. Tank volume is a separate inventory value, not a tested settling time.

Which layout details need separate review?

Tank volumes: R 350 AB 350 l; R 750 AB 750 l. Printed dimensions: 1,150 x 760 x 520 mm versus 1,990 x 970 x 520 mm. Dirty-water inlet height: 440 mm versus 440 mm. Check a current layout drawing and gravity-feed levels; the footprint is not a service-clearance envelope.

Does this comparison approve cleaning performance?

The source describes cascade precipitation/separation of metal and media fines, removable partitions and an adjustable pulse-controlled compressed-air diaphragm pump. It does not give a removal curve, particle cut size or sludge-cleaning interval. No. A representative fluid trial and agreed inlet/outlet measurements are required. This reference does not establish discharge permission or current supplier configuration.

What does the interactive user-input review calculate?

The tool converts your flow between litres per minute and litres per hour and optionally multiplies that liquid quantity by your solids concentration in g/l, divided by 1000. The result is input-derived solids mass rate in kg/h, not captured sludge, wet cake, chemical dose or dewatering performance. It compares your quantity only with a printed catalog reference, preserves approximate labels and exports current inputs. At or below the reference still requires a trial.

Related trial and inspection tools

Discuss your fluid-trial requirements with Jintaijin

Prepare a high-appearance machinery review

Use this local checker to identify missing part and inspection information. It prepares a technical-review brief; it does not approve a machine, process recipe or production result.

Complete the part details to prepare a review brief.

Open the enquiry form for this page

Plan batch capacity from trial measurements

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact