Jintaijin | Independent versioned catalog reference

Roesler RT 250 Euro-DH vs RT 550 Euro-DH: dryer catalog comparison

Compare RT 250 Euro-DH and RT 550 Euro-DH from the Roesler dryer factsheet, physical page 1, revision 04/2023. Read the exact source labels, original ratings and options side by side. Choose one of two catalog-field profiles, enter optional maxima in millimetres and export the current comparison for supplier review. Use current drawings and workpiece trials to confirm the offered configuration and drying process.

Roesler RT 250 Euro-DH vs RT 550 Euro-DH: dryer catalog comparison - catalog-dimensions diagram - Jintaijin
Original catalog dimensions diagram for this pair. Data illustration from factsheet page 1, revision04/2023.

Compare exact models and original source fields

Factsheet fieldRT 250 Euro-DHRT 550 Euro-DH
A – (mm) *31,035 mm1,220 mm
B – Feed height (mm) *3860 mm940 mm
C – Discharge height (mm) *3845 mm985 mm
D – (mm)1,380 mm1,770 mm
E – (mm)1,220 mm1,620 mm
F – (mm)304 mm410 mm
G – (mm)600 mm610 mm
H – Width of separation sieve (mm)325 mm430 mm
J – (mm)1,280 mm1,695 mm
Loading chute (b)530 [unit not explicit / notation retained]650 [unit not explicit / notation retained]
Loading chute (h)130 [unit not explicit / notation retained]150 [unit not explicit / notation retained]
Maximum components dimension (diagonal measurement) (l)up to 135 [unit not explicit / notation retained]up to 290 [unit not explicit / notation retained]
Drive speed (Upm)1,500 Upm1,500 Upm
Drive power (kW)0.75 kW3 kW
Heater power (kW)1,75/3,5 *2 kW2,1/4,2 *2 kW

Drive power (kW): 0.75 kW versus 3 kW; Heater power (kW): 1,75/3,5 *2 kW versus 2,1/4,2 *2 kW; Drive speed (Upm): 1,500 Upm versus 1,500 Upm.

The complete source table is shown with its original labels and notation. Unit-ambiguous fields, stages, ranges and unselected options remain raw; the query only screens cleared numeric dimension fields.

Compare your catalog-field maxima

Select a profile to see the three exact field names. Leave all three inputs blank for comparison, or enter all three positive decimal maxima in mm. Switching profiles clears previous values so one condition cannot inherit another condition’s limits.

Compare source fields or enter all three optional maxima (mm).
Roesler RT 250 Euro-DH vs RT 550 Euro-DH: dryer catalog comparison - secondary-fields diagram - Jintaijin
Original secondary fields diagram for this pair. Data illustration from factsheet page 1, revision04/2023.

Review the two field conditions separately

For source dimensions, D – (mm) is 1,380 mm versus 1,770 mm; E – (mm) is 1,220 mm versus 1,620 mm; A – (mm) *3 is 1,035 mm versus 1,220 mm. These named fields are compared independently; they do not prove installation clearance, part fit or drying suitability.

For transfer heights, B – Feed height (mm) *3 is 860 mm versus 940 mm; C – Discharge height (mm) *3 is 845 mm versus 985 mm; H – Width of separation sieve (mm) is 325 mm versus 430 mm. These named fields are compared independently; they do not prove installation clearance, part fit or drying suitability.

Every result names its selected fields and retains the original source record. A field maximum is a numerical query on a catalog value. In particular, aperture and passage values do not constitute maximum permissible workpiece geometry. Consult the drawing and a trial with actual parts, drying media and loading arrangements.

Roesler RT 250 Euro-DH vs RT 550 Euro-DH: dryer catalog comparison - source-ratings diagram - Jintaijin
Original source ratings diagram for this pair. Data illustration from factsheet page 1, revision04/2023.

Prepare a supplier review and sample trial

Request confirmation of heater-control stages, the offered height arrangement and transfer heights. Check drying-media separation and actual workpiece diagonal using a supplier-approved drawing; the table diagonal row has no explicit unit. RT 1500 Euro has no DH suffix because the source excludes that version.

Record the incoming moisture condition, workpiece geometry, material, sensitivity, handling and separation criteria before requesting a trial. Ask for measured drying outcomes and cycle or residence conditions for the offered setup. This catalog record does not establish acceptable residual moisture, finish quality, corrosion behavior, production output or utility consumption.

Source: Roesler dryer factsheet, physical page 1, revision04/2023. The EN.148.19 revision04/2023 dryer brochure, physical page 5, supplies drawing and label context from the same publisher.

Confirm current configuration, options and availability with the manufacturer. No Jintaijin equivalence or manufacturer partnership is established.

Questions about this pair

What source fields differ between RT 250 Euro-DH and RT 550 Euro-DH?

For source dimensions, D – (mm) is 1,380 mm versus 1,770 mm; E – (mm) is 1,220 mm versus 1,620 mm; A – (mm) *3 is 1,035 mm versus 1,220 mm. These named fields are compared independently; they do not prove installation clearance, part fit or drying suitability. Drive power (kW): 0.75 kW versus 3 kW; Heater power (kW): 1,75/3,5 *2 kW versus 2,1/4,2 *2 kW; Drive speed (Upm): 1,500 Upm versus 1,500 Upm.

Which second field profile is available?

For transfer heights, B – Feed height (mm) *3 is 860 mm versus 940 mm; C – Discharge height (mm) *3 is 845 mm versus 985 mm; H – Width of separation sieve (mm) is 325 mm versus 430 mm. These named fields are compared independently; they do not prove installation clearance, part fit or drying suitability.

Can these dryer ratings establish throughput or operating cost?

Request confirmation of heater-control stages, the offered height arrangement and transfer heights. Check drying-media separation and actual workpiece diagonal using a supplier-approved drawing; the table diagonal row has no explicit unit. RT 1500 Euro has no DH suffix because the source excludes that version. Catalog powers are ratings, not measured consumption. No selected heat stage, cycle time, kg/hour or output guarantee is calculated.

What does a passing maximum-field test mean?

It means each of the three selected source fields is at or below the maximum you entered for that named field. These are independent catalog queries, including aperture or loading fields where selected. They do not establish that a part fits, a dryer fits an installation space or a process will work. Leave all three inputs blank for a comparison, or enter all three positive decimal maxima. Confirm the source revision, offered options, clearance, workpiece handling and sample-trial requirements with the supplier.

Related trial and inspection tools

Discuss your workpiece and sample-trial requirements with Jintaijin

Prepare a high-appearance machinery review

Use this local checker to identify missing part and inspection information. It prepares a technical-review brief; it does not approve a machine, process recipe or production result.

Complete the part details to prepare a review brief.

Open the enquiry form for this page

Plan batch capacity from trial measurements

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact