Jintaijin | Independent versioned catalog reference

Roesler RZ 120 M vs RZ 150 A: liquid-cleaning catalog comparison

Compare RZ 120 M and RZ 150 A using the Roesler centrifuge factsheet, physical page 1, revision 07/2024. Keep liquid flow, sludge volume or mass, power and options on their printed basis. Filter the fields, enter your own liquid-flow requirement and optional solids concentration, and export the current review record. Confirm actual cleaning performance and the offered configuration through supplier drawings and a representative fluid trial.

Roesler RZ 120 M vs RZ 150 A: liquid-cleaning catalog comparison - liquid-flow diagram - Jintaijin
Original liquid flow data diagram for this model pair; factsheet page 1, revision07/2024.

Read each source field on its own basis

Field groupRZ 120 MRZ 150 A
FlowMaximum throughput (l/min)
max. 120 l/min
Maximum throughput (l/min)
max. 150 l/min
SludgeCapacity sludge basket (dm³)
7.5 - 10.0 dm³
Maximum sludge load (kg)
55 kg
TemperatureTemperature resistance (° C)
50 °C
Temperature resistance (° C)
50 °C
ForceCentrifugal force (g)
1,750 g
Centrifugal force (g)
approx. 1,800 g
MotorMotor power (kW)
5.0 kW
Motor power (kW)
11/15 kW
SpeedSpeed (RPM)
2,930 RPM
Speed (RPM)
max. 2,650 RPM

The printed liquid-flow entry is max. 120 l/min for RZ 120 M and max. 150 l/min for RZ 150 A. The source uses maximum litres per minute; multiplying the numerical maximum by 60 changes the reporting unit to litres per hour. This conversion does not establish actual separation performance. RZ 60 M and RZ 120 M are semi-automatic in the reviewed brochure, whereas RZ 150 A uses automatic sludge removal.

Review source fields and your fluid inputs

Choose a field group. Flow is optional; solids concentration requires flow. No process values are prefilled. Catalog comparisons do not select a centrifuge or prove the desired cleaning effect.

Compare the source fields, or enter your own flow and optional solids concentration.
Roesler RZ 120 M vs RZ 150 A: liquid-cleaning catalog comparison - sludge-basis diagram - Jintaijin
Original sludge basis data diagram for this model pair; factsheet page 1, revision07/2024.

Separate fluid load from collected sludge

RZ 120 M: Capacity sludge basket (dm³) = 7.5 - 10.0 dm³; RZ 150 A: Maximum sludge load (kg) = 55 kg. Volume and mass are separate source bases. A range does not select a basket insert, and a volume does not establish a sludge mass without density and loading evidence.

The optional incoming-solids calculation uses your own flow and concentration. It does not infer captured solids, residual moisture, sludge density, cake volume or basket-fill duration. Ask the supplier to establish these quantities with the actual liquid and an agreed cleaning target before selecting a discharge or handling schedule.

Record liquid composition, temperature, solids concentration, particle-size distribution, material densities, emulsified or free oil and the desired cleaning effect. Also record variability during a shift, collection and return paths, tank arrangements and sample handling. A nominal maximum flow cannot replace this fluid-specific review.

Roesler RZ 120 M vs RZ 150 A: liquid-cleaning catalog comparison - power-basis diagram - Jintaijin
Original power basis data diagram for this model pair; factsheet page 1, revision07/2024.

Prepare a source-backed supplier review

RZ 120 M: Motor power (kW) = 5.0 kW; RZ 150 A: Motor power (kW) = 11/15 kW. Original options and catalog averages remain visible; this tool does not turn them into measured electricity use for your process.

Request an offered configuration with current electrical, tank, cooling, dosing, sludge-removal and access details. Specify how inlet and outlet samples will be collected and how the required cleaning effect will be measured. Obtain a trial result rather than adopting a catalog capacity as guaranteed performance. No installation dimensions or floor-loading approval is supplied by the selected tables.

Source: Roesler centrifuge factsheet, physical page 1, revision07/2024. Industrial-liquid cleaning centrifuge brochure supplies RZ context. RZ120M-3PH has conflicting official flow entries and is excluded from this tool.

This independent catalog reference does not establish current availability, Jintaijin equipment equivalence or manufacturer partnership.

Questions about this pair

How do RZ 120 M and RZ 150 A differ in catalog liquid flow?

The printed liquid-flow entry is max. 120 l/min for RZ 120 M and max. 150 l/min for RZ 150 A. The source uses maximum litres per minute; multiplying the numerical maximum by 60 changes the reporting unit to litres per hour. This conversion does not establish actual separation performance. RZ 60 M and RZ 120 M are semi-automatic in the reviewed brochure, whereas RZ 150 A uses automatic sludge removal.

Can the sludge entries be used to set an emptying interval?

RZ 120 M: Capacity sludge basket (dm³) = 7.5 - 10.0 dm³; RZ 150 A: Maximum sludge load (kg) = 55 kg. Volume and mass are separate source bases. A range does not select a basket insert, and a volume does not establish a sludge mass without density and loading evidence. No. Incoming solids, captured solids and wet cake are different quantities. Density, capture efficiency, cake moisture, usable capacity and loading pattern would need separate evidence.

Do the power entries predict operating cost?

RZ 120 M: Motor power (kW) = 5.0 kW; RZ 150 A: Motor power (kW) = 11/15 kW. Original options and catalog averages remain visible; this tool does not turn them into measured electricity use for your process. No current duty cycle, fluid-specific trial or energy measurement protocol is established by this record.

What does the interactive flow and solids review calculate?

The tool converts your flow input between l/min and l/h and, when you also enter solids concentration in g/l, computes incoming solids in kg/h as flow_l/h × concentration_g/l ÷ 1000. It compares your flow only against a scalar printed catalog reference; ranges keep a no-value-selected status. At or below a reference is not approval of cleaning performance. The computed solids are your input mass balance, not captured sludge, part throughput or an emptying schedule. Export uses the current field group and inputs.

Related trial and inspection tools

Discuss your workpiece and fluid-trial requirements with Jintaijin

Prepare a high-appearance machinery review

Use this local checker to identify missing part and inspection information. It prepares a technical-review brief; it does not approve a machine, process recipe or production result.

Complete the part details to prepare a review brief.

Open the enquiry form for this page

Plan batch capacity from trial measurements

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact