Compare Z 1000 ASS-II-Turbo and Z 800 K HA Turbo-Floc using the Roesler centrifuge factsheet, physical page 2, revision 07/2024. Keep liquid flow, sludge volume or mass, power and options on their printed basis. Filter the fields, enter your own liquid-flow requirement and optional solids concentration, and export the current review record. Confirm actual cleaning performance and the offered configuration through supplier drawings and a representative fluid trial.
Read each source field on its own basis
| Field group | Z 1000 ASS-II-Turbo | Z 800 K HA Turbo-Floc |
|---|---|---|
| Speed | Max. rotational speed (RPM) 2,770 RPM | Max. rotational speed (RPM) 2,930 RPM |
| Force | Max. “g” value 2,000 g | Max. “g” value 1,750 g |
| Sludge volume | Max. sludge volume (l) 28 l | Max. sludge volume (l) 11 l |
| Sludge mass | Drum capacity (kg) 30 kg | basket capacity (kg) 28 kg |
| Flow | Capacity 1 (l/h) 800 - 3,500 2 l/h | Capacity1 (l/h) 1,200 l/h |
| Installed | Installed power (kW) 11 kW | Installed power (kW) 5.0 kW |
| Average | Average power draw (kW) 3 6.5 kW | Average power draw (kW) 2.2 kW |
| Dirty tank | Dirty water tank (l) optional 3 700/1,000/2,000 l | Dirty water tank (l) 340 l |
| Clean tank | Clean water tank (l) optional 700/1,000/2,000 l | Clean water tank (l) 400 l |
| Cooling | Cooling of the process water Option | Cooling of the process water optional |
| Dosing | Automatic water and compound replenishment dosing system Option | Automatic water and compound replenishment dosing system optional |
The printed liquid-flow entry is 800 - 3,500 2 l/h for Z 1000 ASS-II-Turbo and 1,200 l/h for Z 800 K HA Turbo-Floc. These process-water entries are in litres per hour and depend on solids load and the desired cleaning effect. The Z1000 range and its separate lower-solids-load footnote are retained without selecting an operating rate. Tank configuration and sludge handling require separate review.
Review source fields and your fluid inputs
Choose a field group. Flow is optional; solids concentration requires flow. No process values are prefilled. Catalog comparisons do not select a centrifuge or prove the desired cleaning effect.
Separate fluid load from collected sludge
Z 1000 ASS-II-Turbo: Max. sludge volume (l) = 28 l, Drum capacity (kg) = 30 kg; Z 800 K HA Turbo-Floc: Max. sludge volume (l) = 11 l, basket capacity (kg) = 28 kg. Volume and mass are separate source bases. A range does not select a basket insert, and a volume does not establish a sludge mass without density and loading evidence.
The optional incoming-solids calculation uses your own flow and concentration. It does not infer captured solids, residual moisture, sludge density, cake volume or basket-fill duration. Ask the supplier to establish these quantities with the actual liquid and an agreed cleaning target before selecting a discharge or handling schedule.
Record liquid composition, temperature, solids concentration, particle-size distribution, material densities, emulsified or free oil and the desired cleaning effect. Also record variability during a shift, collection and return paths, tank arrangements and sample handling. A nominal maximum flow cannot replace this fluid-specific review.
- Catalog liquid flow is not finished-workpiece throughput.
- Sludge volume and mass are separate source fields; no density, basket-fill duration or emptying interval is inferred.
- Ranges, approximate force, motor options, missing tank entries and unspecified options remain raw; missing is not zero.
- No residence time, separation result, particle cut, measured energy use, actual flow guarantee, current build or Jintaijin equivalence is established.
- Capacity depends on solids load and desired cleaning effect (footnote1).
- Z1000 range remains 800–3500 l/h; footnote2 separately lists 12000 l/h with a lower solid particle load. Neither is selected for a real process.
- Average power draw is a catalog entry with no measurement protocol supplied here; no user energy consumption is predicted.
- Footnote3 says higher liquid volumes upon request; its superscript on average power is retained without inferring a measurement basis.
- Z800 basket capacity and Z1000 drum capacity labels remain distinct. Optional tank volumes and cooling/dosing are not selected.
Prepare a source-backed supplier review
Z 1000 ASS-II-Turbo: Installed power (kW) = 11 kW, Average power draw (kW) 3 = 6.5 kW; Z 800 K HA Turbo-Floc: Installed power (kW) = 5.0 kW, Average power draw (kW) = 2.2 kW. Original options and catalog averages remain visible; this tool does not turn them into measured electricity use for your process.
Request an offered configuration with current electrical, tank, cooling, dosing, sludge-removal and access details. Specify how inlet and outlet samples will be collected and how the required cleaning effect will be measured. Obtain a trial result rather than adopting a catalog capacity as guaranteed performance. No installation dimensions or floor-loading approval is supplied by the selected tables.
Source: Roesler centrifuge factsheet, physical page 2, revision07/2024. Industrial-liquid cleaning centrifuge brochure supplies RZ context. RZ120M-3PH has conflicting official flow entries and is excluded from this tool.
This independent catalog reference does not establish current availability, Jintaijin equipment equivalence or manufacturer partnership.
Questions about this pair
How do Z 1000 ASS-II-Turbo and Z 800 K HA Turbo-Floc differ in catalog liquid flow?
The printed liquid-flow entry is 800 - 3,500 2 l/h for Z 1000 ASS-II-Turbo and 1,200 l/h for Z 800 K HA Turbo-Floc. These process-water entries are in litres per hour and depend on solids load and the desired cleaning effect. The Z1000 range and its separate lower-solids-load footnote are retained without selecting an operating rate. Tank configuration and sludge handling require separate review.
Can the sludge entries be used to set an emptying interval?
Z 1000 ASS-II-Turbo: Max. sludge volume (l) = 28 l, Drum capacity (kg) = 30 kg; Z 800 K HA Turbo-Floc: Max. sludge volume (l) = 11 l, basket capacity (kg) = 28 kg. Volume and mass are separate source bases. A range does not select a basket insert, and a volume does not establish a sludge mass without density and loading evidence. No. Incoming solids, captured solids and wet cake are different quantities. Density, capture efficiency, cake moisture, usable capacity and loading pattern would need separate evidence.
Do the power entries predict operating cost?
Z 1000 ASS-II-Turbo: Installed power (kW) = 11 kW, Average power draw (kW) 3 = 6.5 kW; Z 800 K HA Turbo-Floc: Installed power (kW) = 5.0 kW, Average power draw (kW) = 2.2 kW. Original options and catalog averages remain visible; this tool does not turn them into measured electricity use for your process. No current duty cycle, fluid-specific trial or energy measurement protocol is established by this record.
What does the interactive flow and solids review calculate?
The tool converts your flow input between l/min and l/h and, when you also enter solids concentration in g/l, computes incoming solids in kg/h as flow_l/h × concentration_g/l ÷ 1000. It compares your flow only against a scalar printed catalog reference; ranges keep a no-value-selected status. At or below a reference is not approval of cleaning performance. The computed solids are your input mass balance, not captured sludge, part throughput or an emptying schedule. Export uses the current field group and inputs.