Compare CD 110 and CD 200 using the official Walther Trowal CD brochure marked 06/14, physical PDF page2. Filter 10 source fields, record your part, separation, site and acceptance questions, and download the current review. Conditional volume, diagonal limits and drive rows remain versioned references. The separately captured current web table is not merged into a current offer.

Walther Trowal CD 110 vs CD 200 circular vibrator catalog comparison - conditional-bowl-volume diagram - Jintaijin
Original source-data diagram; Walther Trowal 06/14, physical PDF page2. No actual trial or current configuration approval.

Compare catalog fields and record your review questions

Choose a source field group; optionally record your own review requirements.

Versioned catalog rows

Source fieldCD 110CD 200
Work bowl gross volume (L)110200
Conditional usable volume (L)7392
Largest workpiece dimension measured diagonally (mm)160180
Total separation screen area (cm2)1,6322,097
Standard drive power at 1,500 rpm (kW)1.0 kW1.0 kW
Standard motor speed entry (rpm; equipment basis)1,000/1,5001,000/1,500
Maximum centrifugal force (N)17,54018,710
Total weight, empty (kg)427516
Catalog accessory magnetic separator referenceMS 101x14MS 101x14
Catalog accessory vibratory drier referenceG 100G 200

Keep bowl volume separate from part batch load

The 06/14 PDF lists CD 110 with 110 L gross and 73 L conditional usable volume; CD 200 has 200 L gross and 92 L conditional usable volume. The footnote ties the media-to-workpiece ratio to geometry, material and delicacy or nicking risk. Neither column supplies a universal part-only load, bulk density, daily output or cycle time. Record the actual part and media constraints before a representative sample trial.

Review the diagonal and separation interface

The listed diagonal limits are 160 mm for CD 110 and 180 mm for CD 200. A single diagonal value cannot prove motion clearance, nesting, lodging risk, contact damage or complete unloading. Separation-screen areas are 1,632 cm2 and 2,097 cm2, respectively. Screen area does not establish separation speed, aperture, media retention or workpiece carry-out. The CD brochure explicitly lists a pneumatic separation flap as standard for CD 400, CD 600 and CD 1200. Do not extend that list to CD 800 or assume a manual/pneumatic configuration without the offered drawing.

Walther Trowal CD 110 vs CD 200 circular vibrator catalog comparison - diagonal-and-separation-review diagram - Jintaijin
Original source-data diagram; Walther Trowal 06/14, physical PDF page2. No actual trial or current configuration approval.

Keep drive rows tied to their version

CD 110 lists 1.0 kW at 1,500 rpm; CD 200 lists 1.0 kW. Their standard speed entries are 1,000/1,500 and 1,000/1,500. Two-speed alternatives are not a continuous recommended processing range. Inverter maxima are equipment limits, not a validated setpoint. Drive power is not measured energy consumption or total connected load, and no energy cost or productivity is calculated.

Walther Trowal CD 110 vs CD 200 circular vibrator catalog comparison - standard-drive-version-review diagram - Jintaijin
Original source-data diagram; Walther Trowal 06/14, physical PDF page2. No actual trial or current configuration approval.

Review accessories and supplier drawings

The catalog drier references are G 100 for CD 110 and G 200 for CD 200. Magnetic separator references are MS 101x14 and MS 101x14. These are brochure accessory references, not installation, compatibility, stock or quotation approval. Review discharge interface, part/media separation, drying suitability and material-specific acceptance with the responsible supplier. Lettered drawing dimensions are omitted from this tool; no floor plan or maintenance clearance is inferred.

Current official web table and version differences

No difference was found in the selected numeric rows for this pair. This is a limited comparison, not confirmation that all current specifications agree; drawing, speed, accessory and configuration details remain separate.

Official current CD product page, captured 2026-10-05. This comparison covers selected numeric rows; it is not an exhaustive current configuration reconciliation. Confirm offered model, drawing revision, accessories and process trial separately.

Source and scope

Official CD brochure, 06/14, physical page2; captured 2026-10-05. This is an independent Walther Trowal reference. No Jintaijin supply, partnership, equivalent machine, actual finishing result, medical qualification or current offer is established. User notes are USER_RECORDED_NOT_VERIFIED; diagrams are original source-data references.

Questions about this model pair

How do CD 110 and CD 200 compare in bowl volume?

The 06/14 PDF lists CD 110 with 110 L gross and 73 L conditional usable volume; CD 200 has 200 L gross and 92 L conditional usable volume. The footnote ties the media-to-workpiece ratio to geometry, material and delicacy or nicking risk. Neither column supplies a universal part-only load, bulk density, daily output or cycle time. Record the actual part and media constraints before a representative sample trial.

Do their diagonal limits establish part fit?

The listed diagonal limits are 160 mm for CD 110 and 180 mm for CD 200. A single diagonal value cannot prove motion clearance, nesting, lodging risk, contact damage or complete unloading. Separation-screen areas are 1,632 cm2 and 2,097 cm2, respectively. Screen area does not establish separation speed, aperture, media retention or workpiece carry-out. The CD brochure explicitly lists a pneumatic separation flap as standard for CD 400, CD 600 and CD 1200. Do not extend that list to CD 800 or assume a manual/pneumatic configuration without the offered drawing.

Can their catalog speeds be used as process settings?

CD 110 lists 1.0 kW at 1,500 rpm; CD 200 lists 1.0 kW. Their standard speed entries are 1,000/1,500 and 1,000/1,500. Two-speed alternatives are not a continuous recommended processing range. Inverter maxima are equipment limits, not a validated setpoint. Drive power is not measured energy consumption or total connected load, and no energy cost or productivity is calculated.

Which accessory references require confirmation?

The catalog drier references are G 100 for CD 110 and G 200 for CD 200. Magnetic separator references are MS 101x14 and MS 101x14. These are brochure accessory references, not installation, compatibility, stock or quotation approval. Review discharge interface, part/media separation, drying suitability and material-specific acceptance with the responsible supplier. Lettered drawing dimensions are omitted from this tool; no floor plan or maintenance clearance is inferred.

Does the current official website agree with this PDF version?

No difference was found in the selected numeric rows for this pair. This is a limited comparison, not confirmation that all current specifications agree; drawing, speed, accessory and configuration details remain separate.

Related review tools

Prepare a sample review enquiry

For SurfacePolish equipment discussions, provide the part drawing, finishing objective, separation restrictions and acceptance method. This reference does not confirm supply of third-party machines.

Open the SurfacePolish enquiry form

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact