Walther Trowal CF 800 vs CF 1200 circular vibrator catalog comparison

Compare CF 800 and CF 1200 using the official Walther Trowal CF brochure marked 11/18, physical PDF page2. Filter 10 source fields, record your part, separation, site and acceptance questions, and download the current review. Conditional volume, diagonal limits and drive rows remain versioned references. The separately captured current web table is not merged into a current offer.

Walther Trowal CF 800 vs CF 1200 circular vibrator catalog comparison - conditional-bowl-volume diagram - Jintaijin
Original source-data diagram; Walther Trowal 11/18, physical PDF page2. No actual trial or current configuration approval.

Compare catalog fields and record your review questions

Choose a source field group; optionally record your own review requirements.

Versioned catalog rows

Source fieldCF 800CF 1200
Work bowl gross volume (L)8001,200
Conditional usable volume (L)470700
Largest workpiece dimension measured diagonally (mm)315335
Total separation screen area (cm2)4,9006,300
Total weight (kg; empty basis not stated in CM/CF table)2,1102,650
Standard drive power at 1,500 rpm (kW)6.0 kW8.0 kW
Standard motor speed entry (rpm; equipment basis)1,000 / 1,500 (two rotary speeds; joint row)1,000 / 1,500 (two rotary speeds; joint row)
Maximum centrifugal force (N)100,000142,000
Catalog accessory magnetic separator referenceMS 168x31MS 168x36
Catalog accessory vibratory drier referenceG 500G 1000

Keep bowl volume separate from part batch load

The 11/18 PDF lists CF 800 with 800 L gross and 470 L conditional usable volume; CF 1200 has 1,200 L gross and 700 L conditional usable volume. The footnote ties the media-to-workpiece ratio to geometry, material and delicacy or nicking risk. Neither column supplies a universal part-only load, bulk density, daily output or cycle time. Record the actual part and media constraints before a representative sample trial.

Review the diagonal and separation interface

The listed diagonal limits are 315 mm for CF 800 and 335 mm for CF 1200. A single diagonal value cannot prove motion clearance, nesting, lodging risk, contact damage or complete unloading. Separation-screen areas are 4,900 cm2 and 6,300 cm2, respectively. Screen area does not establish separation speed, aperture, media retention or workpiece carry-out. The CF brochure states a pneumatic separation flap is standard for CF 200 and larger; CF 100 is excluded from that statement. Confirm the actual flap and motor configuration.

Walther Trowal CF 800 vs CF 1200 circular vibrator catalog comparison - diagonal-and-separation-review diagram - Jintaijin
Original source-data diagram; Walther Trowal 11/18, physical PDF page2. No actual trial or current configuration approval.

Keep drive rows tied to their version

CF 800 lists 6.0 kW at 1,500 rpm; CF 1200 lists 8.0 kW. Their standard speed entries are 1,000 / 1,500 (two rotary speeds; joint row) and 1,000 / 1,500 (two rotary speeds; joint row). Two-speed alternatives are not a continuous recommended processing range. Inverter maxima are equipment limits, not a validated setpoint. Drive power is not measured energy consumption or total connected load, and no energy cost or productivity is calculated.

Walther Trowal CF 800 vs CF 1200 circular vibrator catalog comparison - standard-drive-version-review diagram - Jintaijin
Original source-data diagram; Walther Trowal 11/18, physical PDF page2. No actual trial or current configuration approval.

Review accessories and supplier drawings

The catalog drier references are G 500 for CF 800 and G 1000 for CF 1200. Magnetic separator references are MS 168x31 and MS 168x36. These are brochure accessory references, not installation, compatibility, stock or quotation approval. Review discharge interface, part/media separation, drying suitability and material-specific acceptance with the responsible supplier. Lettered drawing dimensions are omitted from this tool; no floor plan or maintenance clearance is inferred.

Current official web table and version differences

CF 1200: power is 8.0 kW in the PDF and 11.0 under the current web label "Max. drive power at 1,500 rpm [kW]". These are unresolved version differences. Keep the PDF reference separate and request the offered specification.

Official current CF product page, captured 2026-10-05. This comparison covers selected numeric rows; it is not an exhaustive current configuration reconciliation. Confirm offered model, drawing revision, accessories and process trial separately.

Source and scope

Official CF brochure, 11/18, physical page2; captured 2026-10-05. This is an independent Walther Trowal reference. No Jintaijin supply, partnership, equivalent machine, actual finishing result, medical qualification or current offer is established. User notes are USER_RECORDED_NOT_VERIFIED; diagrams are original source-data references.

Questions about this model pair

How do CF 800 and CF 1200 compare in bowl volume?

The 11/18 PDF lists CF 800 with 800 L gross and 470 L conditional usable volume; CF 1200 has 1,200 L gross and 700 L conditional usable volume. The footnote ties the media-to-workpiece ratio to geometry, material and delicacy or nicking risk. Neither column supplies a universal part-only load, bulk density, daily output or cycle time. Record the actual part and media constraints before a representative sample trial.

Do their diagonal limits establish part fit?

The listed diagonal limits are 315 mm for CF 800 and 335 mm for CF 1200. A single diagonal value cannot prove motion clearance, nesting, lodging risk, contact damage or complete unloading. Separation-screen areas are 4,900 cm2 and 6,300 cm2, respectively. Screen area does not establish separation speed, aperture, media retention or workpiece carry-out. The CF brochure states a pneumatic separation flap is standard for CF 200 and larger; CF 100 is excluded from that statement. Confirm the actual flap and motor configuration.

Can their catalog speeds be used as process settings?

CF 800 lists 6.0 kW at 1,500 rpm; CF 1200 lists 8.0 kW. Their standard speed entries are 1,000 / 1,500 (two rotary speeds; joint row) and 1,000 / 1,500 (two rotary speeds; joint row). Two-speed alternatives are not a continuous recommended processing range. Inverter maxima are equipment limits, not a validated setpoint. Drive power is not measured energy consumption or total connected load, and no energy cost or productivity is calculated.

Which accessory references require confirmation?

The catalog drier references are G 500 for CF 800 and G 1000 for CF 1200. Magnetic separator references are MS 168x31 and MS 168x36. These are brochure accessory references, not installation, compatibility, stock or quotation approval. Review discharge interface, part/media separation, drying suitability and material-specific acceptance with the responsible supplier. Lettered drawing dimensions are omitted from this tool; no floor plan or maintenance clearance is inferred.

Does the current official website agree with this PDF version?

CF 1200: power is 8.0 kW in the PDF and 11.0 under the current web label "Max. drive power at 1,500 rpm [kW]". These are unresolved version differences. Keep the PDF reference separate and request the offered specification.

Related review tools

Prepare a sample review enquiry

For SurfacePolish equipment discussions, provide the part drawing, finishing objective, separation restrictions and acceptance method. This reference does not confirm supply of third-party machines.

Open the SurfacePolish enquiry form

#+86-592-2381506

Email : info@surface-polish.com

Headquarters address : No. 31, Xinchang Road, Xinyang Industrial Zone, Haicang District, Xiamen

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Preparing secure enquiry form…

Home

Products

whatsapp

contact