Walther Trowal ZA 04 vs ZA 06 automatic peeling centrifuge catalog comparison
Review ZA 04 and ZA 06 from the official ZA brochure marked 06/14, physical PDF page2. Compare 8 source fields and preserve their units and conditional bases. Record your part or water-stream objective, loading or contaminant questions, site requirements and acceptance method. The download uses your current form inputs. Current-web captures and differences remain separate for supplier confirmation.
Compare source rows and record your review
Versioned catalog rows
| Source field | ZA 04 | ZA 06 |
|---|---|---|
| Capacity (L/h; source rating) | 1,000 | 2,000 |
| Rotary-drum sludge capacity (L) | 14 | 28 |
| Centrifugal rating (g; gravity multiple) | 1,920 | 2,417 |
| Waste water tank (L) | 800 | 1,500 |
| Process water tank (L) | 400 | 1,000 |
| Drive type | Direct drive | V-Belt drive |
| Dimensions L x B x H (mm; printed version) | 1,660 x 2,800 x 2,120 | 2,250 x 3,000 x 2,200 |
| Average power consumption (kW; catalog entry) | 4.0 | 7.0 |
Capacity entries for this pair
Capacity (L/h; source rating): ZA 04 1,000; ZA 06 2,000. Rotary-drum sludge capacity (L): ZA 04 14; ZA 06 28. Waste water tank (L): ZA 04 800; ZA 06 1,500. Process water tank (L): ZA 04 400; ZA 06 1,000. The PDF power entries4.0/7.0kW and dimensions differ from the current website. Both captures remain separate; no newest configuration is inferred. Average power is a brochure entry, not metered energy, electrical connection rating or an operating-cost calculation. g is a centrifugal gravity multiple, not grams. Flow capacity does not approve a particular contaminant stream or cleaned-water quality. Options and recycling narrative do not establish installed tanks, flocculant dosage, sludge weight, discharge compliance or water-saving performance. Current-web specific-weight label is retained separately from PDF centrifugal-rating label; equal numeric cells are not proof of equal semantic basis.
Drive entries for this pair
Centrifugal rating (g; gravity multiple): ZA 04 1,920; ZA 06 2,417. Drive type: ZA 04 Direct drive; ZA 06 V-Belt drive. Average power consumption (kW; catalog entry): ZA 04 4.0; ZA 06 7.0. The PDF power entries4.0/7.0kW and dimensions differ from the current website. Both captures remain separate; no newest configuration is inferred. Average power is a brochure entry, not metered energy, electrical connection rating or an operating-cost calculation. g is a centrifugal gravity multiple, not grams. Flow capacity does not approve a particular contaminant stream or cleaned-water quality. Options and recycling narrative do not establish installed tanks, flocculant dosage, sludge weight, discharge compliance or water-saving performance. Current-web specific-weight label is retained separately from PDF centrifugal-rating label; equal numeric cells are not proof of equal semantic basis.
Geometry entries for this pair
Dimensions L x B x H (mm; printed version): ZA 04 1,660 x 2,800 x 2,120; ZA 06 2,250 x 3,000 x 2,200. The PDF power entries4.0/7.0kW and dimensions differ from the current website. Both captures remain separate; no newest configuration is inferred. Average power is a brochure entry, not metered energy, electrical connection rating or an operating-cost calculation. g is a centrifugal gravity multiple, not grams. Flow capacity does not approve a particular contaminant stream or cleaned-water quality. Options and recycling narrative do not establish installed tanks, flocculant dosage, sludge weight, discharge compliance or water-saving performance. Current-web specific-weight label is retained separately from PDF centrifugal-rating label; equal numeric cells are not proof of equal semantic basis.
Keep current-web differences visible
ZA 04 dimension: PDF 1,660 x 2,800 x 2,120; current-web Dimensions (mm) (LxWxH) 1,700x2,500x2,100. ZA 06 dimension: PDF 2,250 x 3,000 x 2,200; current-web Dimensions (mm) (LxWxH) 2,100x3,000x2,350. ZA 04 power: PDF 4.0; current-web Average power consumption (kW) 2. ZA 06 power: PDF 7.0; current-web Average power consumption (kW) 5. Model labels and row labels retain their respective captured versions. Confirm an actual supplier specification before using a current system configuration.
Official current ZA product pageSource and sample-review scope
Official ZA brochure, 06/14, physical page2, captured2026-10-05.
This independent Walther Trowal reference helps prepare a source-bound equipment discussion. It does not establish Jintaijin supply, partnership, equivalent machinery, current offers or customer trials. The tool reports printed values without machine ranking or numerical scoring. Your annotations remain USER_RECORDED_NOT_VERIFIED. Bring a real part or process-water sample, loading or contaminant constraints, site supply details and an acceptance method to the supplier review.
Questions about this model pair
What source distinguishes ZA 04 from ZA 06?
Capacity (L/h; source rating): ZA 04 1,000; ZA 06 2,000. Rotary-drum sludge capacity (L): ZA 04 14; ZA 06 28. Waste water tank (L): ZA 04 800; ZA 06 1,500. Process water tank (L): ZA 04 400; ZA 06 1,000. The PDF power entries4.0/7.0kW and dimensions differ from the current website. Both captures remain separate; no newest configuration is inferred. Average power is a brochure entry, not metered energy, electrical connection rating or an operating-cost calculation. g is a centrifugal gravity multiple, not grams. Flow capacity does not approve a particular contaminant stream or cleaned-water quality. Options and recycling narrative do not establish installed tanks, flocculant dosage, sludge weight, discharge compliance or water-saving performance. Current-web specific-weight label is retained separately from PDF centrifugal-rating label; equal numeric cells are not proof of equal semantic basis.
Can these values predict a load, treatment result or cost?
Use the exact versioned source and row basis; current website values stay separate. Media quantities, volumes and conditional capacity ranges are not approved loads or throughput. Catalog power, speed and processing time are not metered consumption, costs or trial recipes. Dimensions and tank capacities do not establish site fit, installed options or treatment quality. Independent Walther Trowal reference; Jintaijin supply, partnership, equivalence and current offer are not established. User annotations are not verified trials or customer facts.
Which source differences need supplier confirmation?
ZA 04 dimension: PDF 1,660 x 2,800 x 2,120; current-web Dimensions (mm) (LxWxH) 1,700x2,500x2,100. ZA 06 dimension: PDF 2,250 x 3,000 x 2,200; current-web Dimensions (mm) (LxWxH) 2,100x3,000x2,350. ZA 04 power: PDF 4.0; current-web Average power consumption (kW) 2. ZA 06 power: PDF 7.0; current-web Average power consumption (kW) 5. Model labels and row labels retain their respective captured versions. Confirm an actual supplier specification before using a current system configuration.
What must a sample review establish?
This independent Walther Trowal reference helps prepare a source-bound equipment discussion. It does not establish Jintaijin supply, partnership, equivalent machinery, current offers or customer trials. The tool reports printed values without machine ranking or numerical scoring. Your annotations remain USER_RECORDED_NOT_VERIFIED. Bring a real part or process-water sample, loading or contaminant constraints, site supply details and an acceptance method to the supplier review.
Does this page confirm a currently offered Jintaijin equivalent?
No. The source is a versioned third-party catalog. No current Jintaijin equivalent, offered configuration or partnership is established.
Related review tools
Prepare a sample review enquiry
Provide a drawing or process-water description, objective, constraints and acceptance method for a SurfacePolish discussion.
Open the SurfacePolish enquiry form