Query six current flat magnetic finishing model records using a minimum published workpiece capacity and three maximum outside dimensions. The result is a match to stated table fields, not a recommendation to run the entered weight. Keep the working-area dimensions, part geometry, circulation and separation evidence with the equipment comparison.
Enter comparison fields from this equipment family.
The OBD-30 and OBD-100 primary pages carry the same six-column specification table. The query consolidates that repeated family information rather than creating a separate page for each source URL. Published workpiece capacities are 30, 35, 60, 70, 90 and 100 kg. These labels are reference ratings; a particular part load must still be checked in a representative trial.
OBD-30 and OBD-35 share a 1300 × 850 × 750 mm outside envelope, while their listed processing areas differ. OBD-60/70 and OBD-90/100 also share outside-envelope pairs. A model passing the external-size filter therefore does not establish that a particular drawing fits the active working area or receives the intended motion. Read the area record separately and obtain the current layout drawing.
A record remains visible only when published capacity is at least the entered minimum and each published outside axis is no greater than its matching maximum. Equal boundary values are included. Enter length, width and height in the published axis order; do not rotate them silently to obtain a match. The input maxima describe comparison limits and do not reserve operator or service clearance.
The source has different motor ratings across the family even when two models share an outside envelope. The query preserves those ratings but does not rank polishing quality, throughput or energy consumption from them. A drive nameplate value is not a measured average demand, and a larger published rating does not establish that a protected edge will remain acceptable.
Identify the material, incoming burr, feature access, contact-sensitive areas and the target inspection method. Keep the actual load, media identity, settings and observed separation result with the record. Check both the intended finish and protected-feature condition before treating the equipment match as a production decision. No generic magnetic finishing cycle or compound concentration is selected here.
Source tables checked 3 October 2026: Primary model table 1 · Primary model table 2. Published reference fields require confirmation for the supplied build and the intended part trial.
Open the enquiry form with this family reference. Filtering stays in this page and does not submit an enquiry.
Email : info@surface-polish.com